Home > Products > Recirculating Chiller > Non-sealed chiller > -40℃ non-sealed recirculating chiller
Intelligence creates the future
Keywords: Rotary Evaporator, Heating and Cooling Circulator, Recirculating Chiller
Model | DLSB-5/40 | DLSB-10/40 | DLSB-20/40 | DLSB-30/40 | DLSB-50/40 | DLSB-100/40 | ||
Technical data | Temperature range | -40-RT;±1℃ | ||||||
Ambient temperature(℃) | ≤30℃ | |||||||
Optimum ambient humidity | 60% | |||||||
Voltage(V) | 220(Optional 1P 110V) | 380(Optional 3P 220V/3P 480V) | ||||||
Phase(P) | 1 | 3 | ||||||
Frequency(Hz) | 50/60 | |||||||
Power(Kw) | 0.9 | 1.3 | 2.4 | 3.2 | 5.3 | 6 | ||
Cooling capacity(W) | RT | 1900 | 2800 | 5625 | 7500 | 12775 | 17000 | |
0℃ | 1000 | 2500 | 4600 | 6180 | 11575 | 15500 | ||
-40℃ | 170 | 550 | 900 | 900 | 1200 | 2300 | ||
Temperature sensor | PT100 | |||||||
Protection | Overvoltage, time delay, overcurrent, overheating, leakage, protector | |||||||
Compressor | Type | Closed | ||||||
Brand | Danfoss | Tecumseh | ||||||
Power(Kw) | 0.75 | 0.975 | 2.25 | 3 | 5.25 | 5.25 | ||
Current(A) | 3.4 | 8 | 5 | 6 | 10 | 10 | ||
Horsepower | 1 | 1½ | 3 | 3 | 6 | 6½ | ||
Quantity | 1 | |||||||
Refrigerant | R404A | |||||||
Condenser | Type | Air cooling | ||||||
Fan type | External rotor axial flow fan | |||||||
Quantity | 1 | |||||||
Evaporator | Type | Internally threaded copper pipe | ||||||
Flume | Tank volume(L) | 5 | 10 | 20 | 30 | 50 | 100 | |
Opening diameter(mm) | 180 | 240 | 320 | |||||
Size(mm) | 180*160 | 300*220 | 350*250 | 350*250 | 400*400 | 500*500 | ||
External circulation interface | G1/2" inner interface to OD 11mm pagoda interface | G1/2" inner interface to OD 14mm pagoda interface | G1/2" inner interface to OD 16mm pagoda interface | G1/2" inner interface to OD 19mm pagoda interface | ||||
Circulating pump | Type | Shield pump | ||||||
Brand | Shanghai Jingyi | |||||||
Power(W) | 100 | 100 | 100 | 100 | 100 | 280 | ||
Current(A) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 1.5 | ||
Rated head(m) | 6 | 6 | 6 | 6 | 6 | 10 | ||
Rated flow(L/min) | 25 | 25 | 25 | 25 | 25 | 35 | ||
Dimension | Chiller weight(Kg) | 45 | 71 | 96 | 105 | 142 | 180 | |
Packing weight(Kg) | 62 | 98 | 130 | 135 | 190 | 230 | ||
Chiller size | Length(mm) | 480 | 580 | 630 | 630 | 730 | 960 | |
Width(mm) | 350 | 490 | 530 | 530 | 630 | 770 | ||
Height(mm) | 680 | 860 | 1000 | 1000 | 1190 | 1330 | ||
Chiller packing size | Length(mm) | 550 | 660 | 700 | 700 | 790 | 1040 | |
Width(mm) | 430 | 560 | 620 | 620 | 720 | 850 | ||
Height(mm) | 670 | 1000 | 1160 | 1160 | 1340 | 1590 | ||
Packing list | One valve and one roll of raw meal | |||||||
3.6m insulation silicone hose | ||||||||
Instruction manual | ||||||||
Remarks | All data are measured in the factory, and users will have errors in the process of use |