Integrated heater chiller with double jacketed glass reactor

Quick details:

High and low temperature integrated machine
Model PLC-50/40 PLC-50/80 PLC-100/40 PLC-100/80
Volume 17L 35L
Load temperature -40℃~250℃ -80℃~250℃ -40℃~250℃ -80℃~250℃
Cooling capacity 12775-650W 15330-550W 15750-550W 15750-450W
Flow 0~35/ PLC control 0~43/ PLC control
Lift 12m 20m
Voltage 380V
Cooling current 11A 20A 11A 20A
Heating current 12A 18A 12A

18A

Cooling power 5500W 10800W 5600W 11000W
Heating power 6000W 9000W
Compressor Tecumseh/ Dafoss/ Emerson-Coperland/ Bitzer
Circulation pump Linbel magnetic circulation pump/ German imported magnetic
Expansion valve Thermal expansion valve/ electronic expansion valve
Operation panel 7-inch color touch screen, temperature curve display and record
Control system Feedforward PID, model-free self-building tree algorithm, PLC controller
Temp-control PLC control of equipment outlet temperature and material temperature

Glass reactor
Model S212-30L S212-50L S212-80L S212-100L
Colume 30L 50L 80L 100L
Jacket volume 10L 16L 24L 30L
Power 90W 120W 180W
Rotating speed 0~600rpm/ PLC control
Feeding valve 40#
Temperature tube 600mm 650mm 850mm
Compressor Serpentine condenser
Collection device Optional 5~50L collection bottle
Power supply 220V/ 50Hz
Operation panel 7-inch color touch screen, temperature curve display and record
Control system Feedforward PID, model-free self-building tree algorithm, PLC controller
Temp-control PLC control of equipment outlet temperature and material temperature
Frequency Standard
PTFE Standard
Size 70*60*240cm 70*60*245cm 100*75*230cm

Integrated chiller/ heater can not only control its own heating, refrigeration and circulation, but also control the speed of the reactor and the temperature of the material through the PLC touch screen, realizing one-screen multi-control operation, multi-stage temperature control, simplifying the operation, saving labor cost and improving work efficiency.

There is a liquid injection port on the top, a closed circulation system and a plate heat exchanger are adopted; the hydraulic gauge and liquid level display can directly read the value when adding refrigerant to prevent the refrigerant from overflowing.